3717-1-03.4(D) / Cooling - temperature and time control.
Critical TCS foods were not cooled using the proper time and temperature parameters. Observed chicken in prep cooler at 73 degrees after three hours of cooling. Chicken must be at 41 degrees after 6 hours of cooling and must be below 70 degrees after 2 hours of cooling. This is not an approved method of cooling. Please cook chicken night before and cool in walk in cooler for rapid cooling overnight.
To prevent the growth of pathogens, cooked TCS food shall be rapidly cooled: within two hours from 135°F to 70°F, and within a total of six hours from 70°F to 41°F or less; (2) TCS food shall be cooled within 4 hours to 41˚F or less if prepared from ingredients at ambient temperature, such as reconstituted foods and canned tuna; (3) TCS food received in compliance with laws allowing a temperature above 41˚F during shipment from the supplier, shall be cooled within 4 hours to 41˚F or less; (4) Raw eggs shall be received at 45°F or less and immediately placed in refrigerated equipment that maintains an ambient air temperature of 45°F or less.
3717-1-03.4(F)(1) / Time/temperature controlled for safety food - hot and cold holding.
Critical TCS foods were not being held at the proper temperature. Observed prep cooler holding food around 45-47 degrees. Make sure cooler is operating properly to hold food at 41 degrees or below.
To prevent the growth of pathogens, except during preparation, cooking, or cooling, or when time is used as a public health control, TCS food shall be held at 135°F or above (except that roasts cooked using time and temperature parameters in 3717-1-03.3 may be held at 130° F), or at 41°F or less.
3717-1-06.2(C) / Handwashing sinks - hand drying provision.
Critical Observed no towels or hand drying device at the handwashing sink(s).
To prevent contamination by hands, each handwashing sink or group of adjacent handwashing sinks shall beprovided with: Individual, disposable towels; a continuous towel system that supplies the user with a clean towel; a heated-air hand drying device; or a hand drying device that employs an air-knife system that delivers high velocity, pressurized air at ambient temperatures.
3717-1-04.1(KK) / Food equipment - certification and classification.
Repeat Equipment is not approved by a recognized testing agency. Observed household microwave in use.Not NSF approved.
Food equipment that is acceptable for use in a FSO or RFE shall be approved by a recognized food equipment testing agency.
Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 09-February-2015
Comments |
---|
Observed proper date marking. Hair restraints and gloves in use. Thank you! |