3717-1-02.2 (B) / Hands and arms: cleaning procedure
Critical Improper washing of hands and arms. Observed food employee not avoid recontamination of hands after handwashing. Code states food employees must use paper towel or other clean barrier to turn off faucet.
3717-1-03.2(C) / Packaged and unpackaged food - preventing contamination by separation, packaging, and segregation
Critical Repeat Corrected During Inspection Food not properly protected from contamination by separation, packaging, and segregation. Observed food stored under leaking condenser in freezer. Make sure no food is stored under condenser. Food was discarded.
3717-1-04.5(B)(1) / Equipment food-contact surfaces and utensils - cleaning frequency.
Critical Food equipment surfaces not cleaned at required frequency. Observed ice machine with build up of debris inside machine where ice is made. Make sure ice machine is being cleaned behind top panel where ice is made.
3717-1-04.4(N)(1) / Manual and mechanical warewashing equipment, chemical sanitization (chlorine) - temp., pH, concentration, and hardness
Critical Repeat Chlorine sanitizing solution at incorre concentration. Observed dishtank not dispensing 100ppm of chlorine. Sanitize dishes in three compartment sink until dishtank is repaired.
3717-1-03.4(F)(1)(b) / Time/temperature controlled for safety food - cold holding.
Critical Corrected During Inspection TCS foods not being cold held at the proper temperature. Observed food in prep cooler in front of grill temping at 50 degrees. All cold holding is to be 41 degrees or below. Food was discarded, prep cooler not to be used until fixed.
3717-1-03.4(G) / Ready-to-eat, time/temperature controlled for safety food - date marking.
Critical Repeat Corrected During Inspection Refrigerated, ready-to-eat, TCS foods not properly date marked. Observed these foods with an eight day datemark. Datemarking is to be for seven days. Labels were corrected.
3717-1-02.4(A)(2) / PIC - Manager Certification
Facility does not have an employee with manager certification in food protection.
3717-1-04.1(H) / Nonfood-contact surfaces - cleanability
Nonfood-contact surfaces not easily cleanable. Observed rack in walk in cooler with build up of rust. Non food contact surfaces must be smooth and easily cleanable. Resurface or replace rack in walk in.
3717-1-04.5(D) / Nonfood-contact surfaces - cleaning frequency.
Repeat Non-food contact surface(s) not cleaned at the required frequency. Observed build up of debris on racks in walk in cooler. Clean racks.
3717-1-06.4(A) / Repairing.
Physical facilities not maintained in good repair. Observed damage to walk in cooler floor in the corner. Fix floor in the walk in within 30 days.
3717-1-06.4(A) / Repairing.
Physical facilities not maintained in good repair. Observed wall in walk in cooler starting to seperate. Fix wall so that there is no seperation.-30 days
3717-1-20(B) / Specifications for replacing equipment and facilities in existing facilities
No handsink in bar area. Code states that anywhere there is warewashing there must be a handsink. Please have plan for handsink within 30 days.
Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard/Critical Control Point
Inspection Date: 27-December-2023