3717-1-03.4(F)(1) / Time/temperature controlled for safety food - hot and cold holding.
Critical Repeat TCS foods were not being held at the proper temperature. Observed lettuce and cottage cheese on salad bar at 47F and 48F respectively. Product discarded.
To prevent the growth of pathogens, except during preparation, cooking, or cooling, or when time is used as a public health control, TCS food shall be held at 135°F or above (except that roasts cooked using time and temperature parameters in 3717-1-03.3 may be held at 130° F), or at 41°F or less.
3717-1-04.1(Y) / Temperature measuring devices.
Cold or hot holding equipment did not contain a thermometer, or the thermometer was not correctly placed. No hanging thermometer observed in walk in cooler.
A properly designed temperature measuring device as specified in this rule shall be located in the warmest part of a cooling unit or the coolest part of a food warming unit.
3717-1-04.4(A)(1) / Equipment - good repair and proper adjustment.
Equipment and/or components are not maintained in good working order. Observed walk in cooler holding am ambient air between 45-47F. Cooler shall be repaired immediately and product moved out until holding is adequate.
Equipment shall be maintained in a state of repair and condition that meets the requirements specified under rules 3717-1-04 and 3717-1-04.1 of this code.
3717-1-04.5(D) / Nonfood-contact surfaces - cleaning frequency.
Observed accumulation of soil residue on nonfood-contact surfaces. Observed build up on hood above oven and fryers.
Nonfood-contact surfaces of equipment shall be cleaned at a frequency necessary to preclude accumulation of soil residues.
Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 19-May-2015
Comments |
---|
Hair restraints, gloves and thermometer available. Quaternary Ammonium sanitizer in three compartment sink at 300ppm and in bucket at 200ppm. Test kits available. Hand sink fully stocked with soap and paper towels. Temperatures on CCP of same date. |