3717-1-02.4(B) / Person in charge: demonstration of knowledge.
Critical The person in charge was unable to demonstrate proper knowledge of food safety and prevention such as cooling methods. When cooling food item, place it in an ice bath, (or) break into smaller amounts and ice bath (or) place in pans 2-inches deep and place in walk-in cooler uncovered. Cooling process can be difficult, but it is very important to monitor both time and temperature. Monitor time and temperature of all cooling food items. Cool from 135° to 70° F in 2 hours and 70°-41° F in additional 4 hours.
If food is placed in cooling equipment, uncover container to promote rapid heat release.
To prevent or correct factors that may cause foodborne illness, based on the risks inherent to the food operation, during inspections and upon request, the person in charge shall demonstrate to the licensor the applicable food safety knowledge at the time of inspection.
3717-1-03.4(F)(1) / Time/temperature controlled for safety food - hot and cold holding.
Critical Repeat TCS foods were not being held at the proper temperature. Observed TCS food items (chicken breast, chicken strips, turkey, steak, and tuna) holding above 41F during inspection. Refer to CCP for temperature log.
To prevent the growth of pathogens, except during preparation, cooking, or cooling,TCS food shall be held at 41°F or less.
3717-1-04.1(C) / Food-contact surfaces - cleanability
Critical Food contact surfaces were not easily cleanable, or not designed/constructed properly. Observed cracked container lids. Once containers are damaged or broken, remove from use.
To prevent the growth of pathogens, Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams, cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Except for cooking oil storage tanks, distribution lines for cooking oils, or beverage syrup lines or tubes; accessible for cleaning and inspection by one of the following methods: (a) Without being disassembled; (b) By disassembling without the use of tools; or (c) by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
3717-1-04.4(N)(3) / Manual and mechanical warewashing equipment, chemical sanitization (quaternary ammonium) - temp., pH, concentration, and hardness
Critical Corrected During Inspection A quaternary ammonium sanitizing solution did not meet the minimum requirements for temperature, concentration, and/or water hardness. Observed quaternary ammonium above 400 ppm in sanitizer bucket. Quaternary ammonium must be maintained between 200-400 ppm to prevent residue/chemical poisoning.
PIC adjusted the concentration solution and used test strips to ensure accuracy.
To prevent pathogen growth, a quaternary ammonium sanitizing solution shall: (a) Have a minimum temperature of 75F,(b) Have a concentration as specified and as indicated by the manufacturer's use directions included in the labeling, (c) Be used only in water with 500 ppm (mg/l) hardness or less, or used in water having a hardness no greater than specified by the manufacturer's label.
3717-1-04.4(A)(1) / Equipment - good repair and proper adjustment.
Repeat Equipment and/or components are not maintained in good working order. Observed top prep cooler holding around 52F at time of inspection. All coolers must run at 41F or less. A phone call for service was placed. Ice was added to the cooler.
Equipment shall be maintained in a state of repair and condition that meets the requirements specified under rules 3717-1-04 and 3717-1-04.1 of this code.
3717-1-04.8(A) / Equipment and utensils - air-drying required.
Equipment and utensils are not being air dried. Observed food containers stacked wet on top of each other.
After cleaning and sanitizing, equipment and utensils shall be air-dried or used after adequate draining before contact with food and utensils, and may not be cloth dried.
Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 03-April-2017
Comments |
---|
Observed handwashing sink properly stocked with hot water, paper towels, and soap during inspection. Observed excellent date marking and handwashing practices at time of inspection. Verified quaternary ammonia at 400 ppm in three compartment sink. Gloves, a digital probe thermometer, and quaternary ammonia test strips were available today. Refer to CCP of the same date for temperature log. NOTES: *Discussed slight build-up on paper towel dispenser. Clean the dispenser. *Ensure to hang mips to allow proper drying to prevent bacteria growth and odor. Discussed today. |