3717-1-03.4(F)(1) / Time/temperature controlled for safety food - hot and cold holding.
Critical Repeat TCS foods were not being held at the proper temperature. Observed sliced tomatoes, shredded cheddar cheese and shredded mozz cheese above 41F. Product was held using ice bath and ice had melted. Product discarded.
To prevent the growth of pathogens, except during preparation, cooking, or cooling, or when time is used as a public health control, TCS food shall be held at 135°F or above (except that roasts cooked using time and temperature parameters in 3717-1-03.3 may be held at 130° F), or at 41°F or less.
3717-1-03.4(F)(1) / Time/temperature controlled for safety food - hot and cold holding.
Critical TCS foods were not being held at the proper temperature. Observed mashed potatoes at 113F on steam table. Product removed to reheat to 165F immediately.
To prevent the growth of pathogens, except during preparation, cooking, or cooling, or when time is used as a public health control, TCS food shall be held at 135°F or above (except that roasts cooked using time and temperature parameters in 3717-1-03.3 may be held at 130° F), or at 41°F or less.
3717-1-04.1(C) / Food-contact surfaces - cleanability
Critical Food contact surfaces were not easily cleanable, or not designed/constructed properly. Observed cracked and chipped ice scoop and shall be discarded immediately.
To prevent the growth of pathogens, Multiuse food-contact surfaces shall be: (1) Smooth; (2) Free of breaks, open seams, cracks, chips, inclusions, pits, and similar imperfections; (3) Free of sharp internal angles, corners, and crevices; (4) Finished to have smooth welds and joints; and (5) Except for cooking oil storage tanks, distribution lines for cooking oils, or beverage syrup lines or tubes; accessible for cleaning and inspection by one of the following methods: (a) Without being disassembled; (b) By disassembling without the use of tools; or (c) by easy disassembling with the use of handheld tools commonly available to maintenance and cleaning personnel such as screwdrivers, pliers, open-end wrenches, and Allen wrenches.
3717-1-04.5(A)(3) / Cleanliness of nonfood-contact surfaces of equipment.
Repeat Non-food contact surfaces of equipment are dirty. Observed build up on and around equipment and shelving throughout kitchen and prep areas.
Nonfood-contact surfaces of equipment shall be kept clean.
3717-1-04.5(C) / Cooking and baking equipment - cleaning frequency
Cooking and/or baking equipment is not cleaned at the required frequency. Observed heavy food debris in hot holding unit by cook line.
Cooking and baking equipment and/or cavities and door seals of microwaves shall be cleaned at least every twenty-four hours.
3717-1-06.4(B) / Cleaning - frequency and restrictions.
Repeat Observed a build-up of dirt and debris throuhout kitchen and prep areas on floors and walls.
The physical facilities shall be cleaned as often as necessary to keep them clean, and cleaning shall be done during periods when the least amount of food is exposed.
Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 18-September-2015
Comments |
---|
Temperatures on CCP of same date. Hair restraints, gloves and thermometers available and observed in use. Hand sinks fully stocked with soap and paper towels. Quaternary Ammonium sanitizer between 150-200ppm at time of inspection. Test strips available. High temperature dish machine reached 180F on final rinse. |