3717-1-03.4(F)(1) / Time/temperature controlled for safety food - hot and cold holding.
Critical TCS foods were not being held at the proper temperature. Hot holding was adjusted to bring temperature of sausage & egg back up, discussed to hot hold they must remain 135F or higher.
To prevent the growth of pathogens, except during preparation, cooking, or cooling, or when time is used as a public health control, TCS food shall be held at 135°F or above (except that roasts cooked using time and temperature parameters in 3717-1-03.3 may be held at 130° F), or at 41°F or less.
Facility Type: Commercial RFE < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 13-June-2017
Comments |
---|
Temperature log: milk 40F, 1/2 & 1/2 39F, yogurt 41F, sausage & egg 111F (up to 135F during inspection), reach-in cooler 37F ambient. Observed stocked hand sink, gloves, Quat 200ppm, test strips available, thermometer Need to obtain Level 2 Food Safety Certification ASAP by a person with an active managerial role. Provided Employee Health Agreement, will email example vomit/ fecal clean up procedure. |