3717-1-03.4(F)(1) / Time/temperature controlled for safety food - hot and cold holding.
Critical TCS food were not being held at proper temperature. Observed TCS food items above 41F at time of inspection. Chili soup 43F, cheddar potato soup 44.5F, chicken noddle soup 44.5F, sausages 42.5F, chicken 42F, turkey 43F.
To prevent the growth of pathogens, except during preparation, cooking, or cooling, or when time is used as a public health control, TCS food shall be held at 135°F or above (except that roasts cooked using time and temperature parameters in 3717-1-03.3 may be held at 130° F), or at 41°F or less.
3717-1-03.4(E) / Cooling methods - temperature and time control.
Observed improper method for cooling TCS foods. Observed food containers in which food is cooling covered in the walk-in cooler. The pans of food must be well vented in order to allow heat to escape.
To prevent the growth of pathogens: (1) Cooling shall be accomplished in accordance with the time and temperature criteria by using one or more of the following methods based on the type of food being cooled: (a) Placing the food in shallow pans; (b) Separating the food into smaller or thinner portions; (c) Using rapid cooling equipment; (d) Stirring the food in a container placed in an ice water bath; (e) Using containers that facilitate heat transfer; (f) Adding ice as an ingredient; or (g) Other effective methods; (2) When placed in cooling or cold holding equipment, food containers in which food is cooling must be arranged so as to provide maximum heat transfer through the container walls and; loosely covered, or uncovered if protected from overhead contamination.
3717-1-04.8(A) / Equipment and utensils - air-drying required.
Equipment and utensils are not being air dried. Observed numerous containers stacked wet on top of each other.
After cleaning and sanitizing, equipment and utensils shall be air-dried or used after adequate draining before contact with food and utensils, and may not be cloth dried.
Facility Type: Commercial FSO < 25000 sq. ft.
[?] Inspection Type: Standard
Inspection Date: 29-September-2016
Comments |
---|
Observed handwashing sinks properly stocked with hot water, paper towels, and soap during inspection. Dish machine is sanitizing properly, it is reaching 180F at final rinse. Verified quaternary ammonia between 200-400 ppm in sanitizer buckets. Gloves, a thermometer, quaternary ammonia test strips were available at time of inspection. Temperature log see CCP of the same date. NOTES: 1.Ensure to hang mops to air dry all times. 2.Discussed proper ice baths. The container should be level with the ice. 3. By March 2017 someone with an active role in the facility must obtain Level 2 Food Safety Certification. 4. Discussed proper cooling methods. Handout provided. 5. Handouts provided on Major Changes to the Ohio Food Code Effective March 1, 2016 and Conditional Employee or Food Employee Reporting Agreement. |