[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(1)(c) / Minimum disinfection residual shall be maintained as required.
Critical Corrected During Inspection The pool free chlorine residual was noted at 0.2ppm. Increase, then maintain the pool free chlorine residual at 1.0ppm minimum. Ms. Knippenberg agreed to Voluntarily Close the pool.

3701-31-04 (B)(6)(j) / All SVRS devices are maintained/ functional and tested
Critical SVRS device test results were not documented. Record the periodic testing of this device.
Correct By: 16-Jul-2021
3701-31-04 (D)(7)(d) / Flow or pressure switch with a shut off valve shall be provided and tested monthly.
Critical Repeat ACC unit test results were not documented. Record the periodic testing of the unit.
Have the ACC unit serviced or replaced with a unit that has a flow or pressure switch with an automatic shut off valve. Provide records indicating that the unit is being tested monthly. Correct By: 16-Jul-2021
3701-31-04(D)(6)(a)(2) / Pool free chlorine disinfectant residual shall be above 1 ppm.
Critical Corrected During Inspection The pool free chlorine residual was noted at 0.2ppm. Increase, then maintain the pool free chlorine residual at 1.0ppm minimum. Ms. Knippenberg agreed to Voluntarily Close the pool.
Do not operate the pool until the chlorine disinfectant residual is at 1 ppm or above.

3701-31-04 (B)(4)(c) / SVRS/APSOS/ACC test results/ service records are maintained
Repeat SVRS device and ACC unit test results were not documented. Record the periodic testing of these items.
The test results/service records for these devices must be kept on site for review. If the device has not been recently serviced, have the device tested immediately and provide documentation of the test results. Correct By: 16-Jul-2021


Inspection Information


[?] Facility Type: Pool

[?] Inspection Type: Standard

[?] Inspection Date: 08-July-2021


Comments
Pool Notes:
1. The pool water is clear
2. Turnover rate=2.1 hours.
3. Filter pressure gauge reads 10psi.
4. ACC unit pH reads 7.4, Free chlorine reads 1.0ppm.
5. SVRS and ACC unit alarms functioned when tested.
6. The report was emailed to the facility.
Contact Scott Bradley,E.H.S. (732-7614) with any questions.