3701-31-04 (B)(6)(t) / Equipment/chemical/storage areas are free of hazards/accessible only to authorized personnel.
Critical Repeat Corrected During Inspection Observed the door to the equipment and chemical storage area to be open at time of inspection. Room was accessible to individuals from the parking lot.
Ensure the equipment and chemical storage areas are accessible to authorized personnel only. Discussed with operator, door was shut and locked at time of inspection.
3701-31-04 (A) / Approval shall be obtained for any construction or alterations of a public swimming pool.
Repeat Observed the chemical disinfection feeder pump to have been replaced with a Mec-O-Matic, Dolphin Series Model No. US50-XA-SAUXXX from a FlexFlow Model No. A1N30A7T.
Complete and submit an Equipment Replacement Notification form for the disinfection feeder to ODH for review and approval.
3701-31-04 (B)(4)(a)(ii) / Combined chlorine is tested daily at pool side prior to use
Combined chlorine was not tested daily at pool side prior to use.
Test for combined chlorine prior to bathers entering the water and every 4 hours the pool is open for use. If ACC is in use combined chlorine must be tested every 12 hours while the pool is in use. For spraygrounds and spray features, the combined chlorine must be tested at 1 spray feature every 6 hours the sprayground or spray feature is in use.
3701-31-04 (B)(6)(p) / Deck surfaces are free of standing water or other hazards.
Repeat Observed the pool deck to be in disrepair and crumbling by the pool main entry hand rail at the shallow end.
Repair areas of the deck where standing water is occurring. If more than 50% of the deck must be replaced, plans must be submitted to the Ohio Department of Health for review and approval.
3701-31-04 (E)(3)(c) / Location of emergency telephone posted when the phone is not visible.
Repeat Sign indicating the location of the emergency device (telephone) was not provided and emergency device was not visible in the pool area.
Ensure that a sign informing patrons of the location of the emergency device is always visible in the pool area.
[?] Facility Type: Pool
[?] Inspection Type: Standard
[?] Inspection Date: 18-August-2022