3701-31-04 (B)(4)(a)(vi) / Total alkalinity is tested weekly
Total alkalinity was not tested for this week. The person in charge at the time of inspection was not aware of the alkalinity test method.
Test total alkalinity at least once/week.
3701-31-04 (E)(2) / The public swimming pool has safety equipment visible
The safety equipment for the pool was not accessible and/or visible. USCG type IV PFD with rope was placed in the storage room.
Place the safety equipment in a clearly visible area and ensure that the equipment is accessible in the event of an emergency.
3701-31-04 (E)(3)(c) / Location of emergency telephone posted when the phone is not visible.
Sign indicating the location of the emergency device (telephone) was not provided and emergency device was not visible in the pool area. As per the person in charge at the time of inspection the telephones located in the club will be used for emergency.
Ensure that a sign informing patrons of the location of the emergency device is always visible in the pool area.
[?] Facility Type: Pool
[?] Inspection Type: Standard
[?] Inspection Date: 26-July-2016
Comments |
---|
1. Pool water was clear. 2. Perimeter was properly secured. 3. Chemical residuals meets code requirements. |