3701-31-04 (B)(1)(e) / Automatic Chemical Controller (ACC) shall function properly.
Critical Repeat Automatic Chemical Controller (ACC) was not functioning properly at the time of the inspection. Pressure switch is still unplugged.
Activate pressure switch. Do not operate the pool when the ACC unit is not functioning properly. Ensure that the ACC unit is functioning properly prior to placing the pool back into operation.
3701-31-04 ( D )(6)(a) / ORP reading shall be 650 millivolts or greater.
Repeat ORP reading was below 650 mV.
Have the ACC unit inspected to determined why the ORP is low.
3701-31-04 (B)(4)(a)(ii) / Combined chlorine is tested daily at pool side prior to use
Repeat Combined chlorine was not tested daily at pool side prior to use.
Test for combined chlorine prior to bathers entering the water and every 4 hours the pool is open for use. If ACC is in use combined chlorine must be tested every 12 hours while the pool is in use. For spraygrounds and spray features, the combined chlorine must be tested at 1 spray feature every 6 hours the sprayground or spray feature is in use.
[?] Facility Type: Pool
[?] Inspection Type: Standard
[?] Inspection Date: 03-August-2015
Comments |
---|
Water clarity, disinfectant residuals and water quality readings meet code requirements at this time. Record keeping was much improved last week. Thanks for your efforts. Keep up the good work. Reagent #3 (required to determine total and combined chlorine residuals) still has not been used this season. Another standard inspection will be conducted (weather permitting) prior to the end of this pool season. |