3701-31-04 (B)(1)(a) / Outlet covers are installed/secured/in compliance
Critical VGB drain covers (Aquastar P9101, five (5) year replacement) are at the facility, but have not been placed on the drains.
Install the covers on the two (2) main drains.
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat The filter system flow meter is not working.
Repair the flow meter so water turnover rates can be determined.
[?] Facility Type: Pool
[?] Inspection Type: Standard
[?] Inspection Date: 26-August-2014
Comments |
---|
Pool Notes: 1. Pressure gauge reads 21psi. 2. Auto Controller pH reads 7.6. 3. The salt system was replaced. Information was updated in the Inventory Sheet. Inspection conducted by Scott Bradley,R.S. 732-7614 |