3701-31-04 (B)(6)(j) / All SVRS devices are maintained/ functional and tested
Critical Repeat Periodic SVRS testing could not be verified. Record periodic SVRS device testing.
Correct By: 26-Sep-2022
3701-31-04 (B)(4)(c) / SVRS/APSOS/ACC test results/ service records are maintained
Repeat SVRS device and ACC unit test results were not recorded. Record periodic testing in records.
The test results/service records for these devices must be kept on site for review. If the device has not been recently serviced, have the device tested immediately and provide documentation of the test results. Correct By: 26-Sep-2022
3701-31-04 (C)(2) / pH is within 7.2 to 7.8
Repeat The pool pH was noted at 8.0. Lower, then maintain the pool pH between 7.2-7.8.
Treat the pool water so that the pH is within the acceptable range. Correct By: 26-Sep-2022
[?] Facility Type: Pool
[?] Inspection Type: Standard
[?] Inspection Date: 14-September-2022
Comments |
---|
Pool Notes: 1. Continue efforts to have the proposed new disinfection system Approved by the Ohio Department of Health. 2. The pool water is fair. Continue efforts to improve the pool water clarity. 3. Turnover rate=2.7 hours. 4. Filter pressure gauge reads 11psi. 5. ACC unit pH reads 7.1. 6. The report was emailed to the facility. Contact Scott Bradley,R.E.H.S. (732-7614) with any questions. |