3701-31-04 (B)(6)(k) / Outlet drain covers are secure/meet ANSI/ASME A112.19.8-2007 requirements.
Critical Repeat Specifications for the one (1) main drain cover could not be located.
Provide specifications (Manufacturer, Model, Install/Replace Dates) for the main drain cover to verify VGB compliance. According to Julie Michelson (Aqua Marine Pool), the "Hayward" cover in the filter room will replace the existing drain cover. Ms. Michelson was told to email CCPH specifications on the cover when it is installed.
3701-31-04 (B)(4)(c) / SVRS/APSOS/ACC test results/ service records are maintained
SVRS and ACC test results/ service records were not maintained.
Test and record periodic evaluations of the SVRS and the ACC units.
3701-31-04 (B)(6)(h) / Required meters and gauges maintained/functional
Repeat The filter pressure gauges are not working.
Repair the pressure gauges so filter pressure readings can be monitored.
[?] Facility Type: Pool
[?] Inspection Type: Standard
[?] Inspection Date: 19-August-2015
Comments |
---|
No other violations observed during the inspection. The pool otherwise looks great! Pool Notes: 1. The 2015 pool license is posted. 2. The pool water is clear. 3. Proper safety equipment is available for use. 4. ACC unit pH noted at 7.8. 5. Pool turnover rate=7.5 hours. 6. The pool pH was between 7.4-7.6. 7. Prior to the start of the 2016 Pool Season, the facility may want to consider repainting the pool deck "No Diving" signage and depth markers. 8. Copy of the report was left with the pool records. Inspection conducted by Scott Bradley,R.S. 732-7614 |