No critical violations were documented at the time of inspection.
No violations were documented at the time of inspection.
[?] Facility Type: Pool
[?] Inspection Type: Follow-up
[?] Inspection Date: 13-June-2022
The following violation(s) have been corrected since the last inspection. |
---|
3701-31-04 ( D )(6)(a)/ORP reading shall be 650 millivolts or greater. The ACC unit ORP was noted at 430mv. Increase, then maintain the reading at 650 mv. Have the ACC unit inspected to determined why the ORP is low. Correct By: 13-Jun-2022 |
3701-31-04 (B)(1)(c)/Minimum disinfection residual shall be maintained as required. The wading pool free chlorine residual was noted at 0ppm. Increase, then maintain the wading pool free chlorine residual at 1.0ppm minimum. Stephanie (Cincinnati Pool Management) agreed to Voluntarily Close the wading pool. Correct By: 13-Jun-2022 |
3701-31-04 (E)(2)(a)(i)/12 ft. non-telescopic reach pole with shepherd's crook is provided 12 ft. non-telescopic reach pole with a shepherd's crook was not provided at the unguarded pool. Provide a reach pole with a shepherd's crook. Provide a 12 ft. non-telescopic reach pole in the pool area at all times. Correct By: 13-Jun-2022 |
3701-31-04(D)(6)(a)(1)/Combined chlorine shall not exceed 1.0 ppm. The wading pool free chlorine residual was noted at 0ppm. Increase, then maintain the wading pool free chlorine residual at 1.0ppm minimum. Stephanie (Cincinnati Pool Management) agreed to Voluntarily Close the wading pool. Treat the pool so that the combined chlorine is less than 1 ppm. |
Comments |
---|
All violations were corrected. Thanks! Pool Notes: 1. The pool water is clear. 2. ACC unit pH noted at 7.9. Upon arrival, the alarm was functioning. 3. The pool pH was between 7.6-7.8. 4. The report was emailed to Ms. Lasota. Contact Scott Bradley,R.E.H.S. (732-7614) with any questions. |