3701-31-04 (D)(6)(a) / Pool free chlorine disinfectant residual is above 1 ppm.
Critical Repeat Pool free chlorine disinfectant residual was below 1 ppm. 0 ppm
Do not operate the pool until the chlorine disinfectant residual is at 1 ppm or above.
3701-31-04 (B)(4)(a)(ii) / Combined chlorine is tested daily at pool side prior to use
Repeat Combined chlorine was not tested daily at pool side prior to use.
Test for combined chlorine prior to bathers entering the water and every 4 hours the pool is open for use. If ACC is in use combined chlorine must be tested every 12 hours while the pool is in use. For spraygrounds and spray features, the combined chlorine must be tested at 1 spray feature every 6 hours the sprayground or spray feature is in use.
3701-31-04 (B)(6)(h) / Required meters and gauges maintained/functional
Repeat Required meters and gauges were not maintained or were not functional while the pool is in operation. #1 sandfilter does not appear to have a functioning pressure guage.
Maintain all meters and gauges in a properly funtioning manner at all times while the pool is in operation.
[?] Facility Type: Pool
[?] Inspection Type: Follow-up
[?] Inspection Date: 21-August-2014
Comments |
---|
Pool open. |