3701-31-04(D)(6)(a)(2) / Pool free chlorine disinfectant residual shall be above 1 ppm.
Critical Corrected During Inspection Upon arrival to the pool the free chlorine level was measured at .6 ppm.
The chlorine feed was increased and the free chlorine level was measured at 1 ppm.
3701-31-04 (B)(4) / The licensee /authorized representative is keeping records
The licensee maintaining operational records on Saturdays and Sundays.
Ensure the pool is tested on the weekend and test results are recorded.
3701-31-04 (B)(4)(a)(iv) / Water temperatures are recorded daily
Water temperatures were not being recorded daily.
Take and record the water temperature at least once/day.
3701-31-04 (B)(4)(a)(vi) / Total alkalinity is tested weekly
Total alkalinity was not tested weekly.
Test total alkalinity at least once/week.
3701-31-04 (E)(3)(a) / "WARNING, NO LIFEGUARD", sign posted
The unguarded pool was in use without the "WARNING, NO LIFEGUARD" sign posted.
Post the WARNING, NO LIFEGUARD sign in a conspicuos location at all times the pool is available for use.
[?] Facility Type: Pool
[?] Inspection Type: Standard
[?] Inspection Date: 04-August-2015
Comments |
---|
-The disinfectant residuals and water quality parameters meet code requirement. -Free chlorine was 1 ppm, ideal range is 2-4 ppm. -All required safety equipment was provided. -The pool perimeter was secure. -The filter pressure was 6 psi. -The pool water is clear. -Turn over rate was 424 minutes. If you have any questions or concerns, call me at (513) 732-7612. |