Sampling Details
Sub Type: Other Special Feature: Location:
Area: 1000 Volume (gallons): 30000 Flow measure reading (gpm): 80 Minimum required flow (gpm): 63
Disinfectant: Sodium Hypochlorite Secondary Disinfectant: ORP: 772 Turnover Rate (min): 375
Total Chlorine (ppm): 1.5 Free Chlorine (ppm): 1.5 Combined Chlorine (ppm): 0 Total Bromine (ppm):
Alkalinity (ppm): 70 Pool water temp ˚F: 85 pH: 7.3 Cyanuric acid (ppm):
Spa water temp ˚F: Spa water replaced every 30 days: Max Allow. Filter Flow (gpm): Max Allow. Flow: Jet pump capacity (gpm):
Max Allow. Flow: SF pump capacity (gpm):
[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(6)(o) / Ladders/stairs/steps are in good repair/slip resistent
Ladders/stairs/steps were not in good repair. Ladder across from hoop was able to be pulled up.
Repair or replace the ladders/stairs/steps so that they are slip resistant and in good repair.


Inspection Information


[?] Facility Type: Pool

[?] Inspection Type: Standard

[?] Inspection Date: 17-June-2021

Comments
Pool Notes:
-Bathrooms clean.
-Safety equipment available.
-Phone properly worked.
-Pool chemicals meet the required code minimum.