Sampling Details | |||
---|---|---|---|
Sub Type: Other | Special Feature: | Location: | |
Area: 1440 | Volume (gallons): 43200 | Flow measure reading (gpm): 0 | Minimum required flow (gpm): 90 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: 549 | Turnover Rate (min): 480 |
Total Chlorine (ppm): 8 | Free Chlorine (ppm): 8 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 60 | Pool water temp ˚F: 80 | pH: 7.5 | Cyanuric acid (ppm): 25 |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): 141 | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(4)(a)(vi) / Total alkalinity is tested weekly
Repeat Total alkalinity was not tested weekly.
Test total alkalinity at least once/week. 3701-31-04 (B)(4)(a)(vii) / Cyanuric acid is tested weekly
Repeat Cyanuric acid was not tested weekly.
Test for cyanuric acid level at least once/week. 3701-31-04 (B)(6)(h) / Required meters and gauges maintained/functional
No flow detected at flow meter.
Repair or replace flow meter so that flow rate can be monitored and turnover rates assured. Maintain all meters and gauges in a properly funtioning manner at all times while the pool is in operation. 3701-31-04 (E)(2)(e) / Working emergency telephone/call box provided.
Repeat Emergency device (telephone) was not working. No dial tone detected at the emergency phone.
Ensure that the emergency device is functioning properly and rings to the emergency response authorities. 3701-31-04 (E)(3)(b) / "Children must be supervised" or "Swimming alone is not recommended" signs posted
Repeat The unguarded pool was in use without the "Swimming alone is not recommended" sign posted.
Post the "Swimming Alone is Not Recommended" sign at all times the pool is available for use.
Comments |
---|
Facility inspection notes: Water clarity, disinfectant residuals, and water quality readings meet minimum code requirements at this time. Safety equipment (unless otherwise noted in this report) provided as required. Follow-up scheduled for Monday July 17, 2017 to verify repair or replacement of emergency phone. |