Sampling Details | |||
---|---|---|---|
Sub Type: Hotel/motel | Special Feature: | Location: | |
Area: 418 | Volume (gallons): 12500 | Flow measure reading (gpm): 45 | Minimum required flow (gpm): 26 |
Disinfectant: Salt | Secondary Disinfectant: | ORP: 820 | Turnover Rate (min): 480 |
Total Chlorine (ppm): 2.5 | Free Chlorine (ppm): 1.5 | Combined Chlorine (ppm): 1 | Total Bromine (ppm): |
Alkalinity (ppm): 110 | Pool water temp ˚F: 82 | pH: 7.4 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): 120 | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
No critical violations were documented at the time of inspection.
No violations were documented at the time of inspection.
The following violation(s) have been corrected since the last inspection. |
---|
3701-31-04(D)(6)(a)(1)/Combined chlorine shall not exceed 1.0 ppm. Combined chlorine was greater than 1.0 ppm. Observed the combined chlorine levels to be 2.0 ppm. Treat the pool so that the combined chlorine is less than 1 ppm. |
3701-31-04 (E)(2)(d)/First aid kit provided First aid equipment was not provided. First aid kit was not properly supplied with disposable gloves. Ensure first aid kit is properly supplied with a minimum of gauze, bandages and disposable gloves. |