Sampling Details | |||
---|---|---|---|
Sub Type: Apartment/Condo | Special Feature: | Location: | |
Area: 1615 | Volume (gallons): 63447 | Flow measure reading (gpm): 135 | Minimum required flow (gpm): 132 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: | Turnover Rate (min): 465 |
Total Chlorine (ppm): 3 | Free Chlorine (ppm): 2.5 | Combined Chlorine (ppm): 0.5 | Total Bromine (ppm): |
Alkalinity (ppm): 120 | Pool water temp ˚F: 82 | pH: 7.3 | Cyanuric acid (ppm): 0 |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(4)(a)(i) / Disinfection residuals are tested daily at pool side at required intervals for pools/automatic chemical controllers/special features
Repeat Disinfection residuals were not tested daily at pool side and/or at the required intervals for pools. A weekend and several week days did not have readings recorded.
Test the disinfection residual every day before bathers enter the water. Disinfection residual must then be tested every 4 hours when an ACC is not in use. 3701-31-04 (B)(4)(a)(iii) / pH is tested daily at pool side at required intervals for pools/automatic chemical controllers/special features
Repeat pH was not tested daily at pool side and/or at required intervals for pools. A weekend and several days did not have recordings.
pH must be tested prior to bathers entering the water and every 4 hours the pool is open for use. 3701-31-04 (B)(4)(a)(iv) / Water temperatures are recorded daily
Repeat Water temperatures were not being recorded daily.
Take and record the water temperature at least once/day. 3701-31-04 (B)(4)(a)(v) / Water clarity are not present
Water clarity was not recorded daily.
Record water clarity daily. 3701-31-04 (B)(4)(c) / SVRS/APSOS/ACC test results/ service records are maintained
Repeat SVRS test results/ service records were not maintained.
The test results/service records for these devices must be kept on site for review. Record SVRS tests monthly, Test the Stingl switch and record the test in the pool records. Must be tested monthly. The SVRS was tested during the inspection and was operating correctly. 3701-31-04 (B)(6)(a) / Pool structure is water tight
The pool structure was cracked and leaking water. A small crack is located in the skimmer basket located near the equipment shed.
Repair the pool structure to a water-tight system. If necessary, consult with the Ohio Department of Health regarding the repair.
Comments |
---|
Facility inspection notes: Water clarity, disinfectant residuals, water quality readings meet minimum code requirements. Signage and safety equipment provided as required. Pool has a leak. There is a small crack in the shallow skimmer basket located near the equipment shed. Repair the crack and see if water level still drops. Pool looks great! Please keep up the good work! If you have any quest |