Sampling Details | |||
---|---|---|---|
Sub Type: Wading Pool | Special Feature: | Location: | |
Area: 144 | Volume (gallons): 1080 | Flow measure reading (gpm): 60 | Minimum required flow (gpm): 9 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: 440 | Turnover Rate (min): 120 |
Total Chlorine (ppm): 0 | Free Chlorine (ppm): 0 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 60 | Pool water temp ˚F: 75 | pH: 7.7 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): 63 | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 ( D )(6)(a) / ORP reading shall be 650 millivolts or greater.
The ACC unit ORP was noted at 430mv. Increase, then maintain the reading at 650 mv.
Have the ACC unit inspected to determined why the ORP is low. Correct By: 13-Jun-2022 3701-31-04 (B)(1)(c) / Minimum disinfection residual shall be maintained as required.
Critical The wading pool free chlorine residual was noted at 0ppm. Increase, then maintain the wading pool free chlorine residual at 1.0ppm minimum. Stephanie (Cincinnati Pool Management) agreed to Voluntarily Close the wading pool.
Correct By: 13-Jun-2022 3701-31-04 (E)(2)(a)(i) / 12 ft. non-telescopic reach pole with shepherd's crook is provided
12 ft. non-telescopic reach pole with a shepherd's crook was not provided at the unguarded pool.
Provide a reach pole with a shepherd's crook.
Provide a 12 ft. non-telescopic reach pole in the pool area at all times. Correct By: 13-Jun-2022 3701-31-04(D)(6)(a)(1) / Combined chlorine shall not exceed 1.0 ppm.
The wading pool free chlorine residual was noted at 0ppm. Increase, then maintain the wading pool free chlorine residual at 1.0ppm minimum. Stephanie (Cincinnati Pool Management) agreed to Voluntarily Close the wading pool.
Treat the pool so that the combined chlorine is less than 1 ppm.
Comments |
---|
Pool Notes: 1. The pool water is clear. 2. ACC unit pH noted at 7.8. Upon arrival, the alarm was functioning. 3. Pool turnover rate=0.3hours. 4. The pool pH was between 7.8-8.0. 5. The report was emailed to Ms. Lasota. Contact Scott Bradley,R.E.H.S. (732-7614) with any questions. |