Sampling Details | |||
---|---|---|---|
Sub Type: Other | Special Feature: | Location: | |
Area: 1696 | Volume (gallons): 52000 | Flow measure reading (gpm): 110 | Minimum required flow (gpm): 109 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: 730 | Turnover Rate (min): 480 |
Total Chlorine (ppm): 6 | Free Chlorine (ppm): 6 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 100 | Pool water temp ˚F: 80 | pH: 7.8 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): 74 | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (A)(1) / Public swimming pool is licensed
Repeat The Swimming Pool License could not be located. Post the 2019 Swimming Pool License.
Comments |
---|
No other violations observed during the inspection. The pool otherwise Looks Great! Pool Notes: 1. ACC unit alarm testing is documented in pool records. The alarm functions when tested. 2. The pool water is clear. 3. Proper safety equipment is available for use. 4. ACC unit pH noted at 7.2. 5. Pool turnover rate=7.9 hours. 6. Filter pressure gauges noted at 13 and 14psi. 7. The report was emailed to Mr. Doud. Contact Scott Bradley,R.S. (732-7614) with any questions. |