Sampling Details | |||
---|---|---|---|
Sub Type: Wading Pool | Special Feature: | Location: | |
Area: 136 | Volume (gallons): 1530 | Flow measure reading (gpm): | Minimum required flow (gpm): |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: | Turnover Rate (min): |
Total Chlorine (ppm): 3 | Free Chlorine (ppm): 3 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): | Pool water temp ˚F: | pH: 8.4 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(2) / Authorized representative is on-site or within 30 minutes of pool location
Repeat Authorized representative was not on-site or within 30 minutes of pool location.
Make arrangements to have an authorized representative available while pool is in operation. 3701-31-04 (B)(4)(a)(ii) / Combined chlorine is tested daily at pool side prior to use
Repeat Combined chlorine was not tested daily at pool side prior to use.
Test for combined chlorine prior to bathers entering the water and every 4 hours the pool is open for use. If ACC is in use combined chlorine must be tested every 12 hours while the pool is in use. For spraygrounds and spray features, the combined chlorine must be tested at 1 spray feature every 6 hours the sprayground or spray feature is in use. 3701-31-04 (C)(2) / pH is within 7.2 to 7.8
Repeat pH was outside the range of 7.2 to 7.8. pH observed at 8.4
Treat the pool water so that the pH is within the acceptable range. Correct By: 19-Jul-2019 3701-31-04 (E)(2)(d) / First aid kit provided
Repeat First aid kit did not contain gloves.
Provide first aid kit complete with gloves.
The following violation(s) have been corrected since the last inspection. |
---|
3701-31-04 (B)(6)(s)/Perimeter barrier is in good repair to prevent unauthorized entry Main gate to pool entrance was not self-closing. Repair gates or doors in order to be self-closing and lockable. Correct By: 16-Jul-2019 |
Comments |
---|
Pool was reopened by inspector after gate observed to be self-closing and self-latching. Thank you for fixing the main gate in a timely manner. Re-inspection scheduled for 7/19 after observing pH above 8.0 for two days straight. Please treat the pool water so that pH is within acceptable range. |