Sampling Details
Sub Type: Spray Ground Special Feature: Location:
Area: 17 Volume (gallons): 600 Flow measure reading (gpm): 55 Minimum required flow (gpm): 20
Disinfectant: Sodium Hypochlorite Secondary Disinfectant: ORP: 790 Turnover Rate (min): 30
Total Chlorine (ppm): 2 Free Chlorine (ppm): 2 Combined Chlorine (ppm): 0 Total Bromine (ppm):
Alkalinity (ppm): 80 Pool water temp ˚F: 81 pH: 7.5 Cyanuric acid (ppm):
Spa water temp ˚F: Spa water replaced every 30 days: Max Allow. Filter Flow (gpm): 44 Max Allow. Flow: Jet pump capacity (gpm):
Max Allow. Flow: SF pump capacity (gpm):
[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(4)(c) / SVRS/APSOS/ACC test results/ service records are maintained
APSOS/ACC test results/ service records were not maintained.
The test results/service records for these devices must be kept on site for review. If the device has not been recently serviced, have the device tested immediately and provide documentation of the test results. ACC / APSOS fuction tested during inspection and found to be functioning satisfactorily.
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat Flow rate of 55-60 gpm exceeds the design flow rate of 44 gpm listed on the sand filter.
To the extent practical, throttle down the flow rate to between 20-44 gpm so as to achieve 30 minute turnover rate without exceeding the flow capacity of the sand filter. All equipment must be maintained in accordance with the manufacturers specifications.


Inspection Information


[?] Facility Type: Special Use Pool

[?] Inspection Type: Standard

[?] Inspection Date: 31-July-2018

Comments
Water clarity, disinfectant residuals, and water quality readings meet minimum code requirements at this time.
Signage, safety equipment, and pool records provided and maintained as required.
ACC / APSOS tested during inspection. Functions properly at this time.
Restroom facilities - clean and supplied.
Pool looks great! Please keep up the good work.