Sampling Details | |||
---|---|---|---|
Sub Type: Apartment/Condo | Special Feature: | Location: | |
Area: 900 | Volume (gallons): 25178 | Flow measure reading (gpm): | Minimum required flow (gpm): 53 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: 7.4 | Turnover Rate (min): 480 |
Total Chlorine (ppm): 3 | Free Chlorine (ppm): 3 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): | Pool water temp ˚F: | pH: 7.6 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): 98 | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (D)(7)(c) / Audible/visual alarm shall activate when unit is malfunctioning or when pH or ORP levels are not acceptable.
Critical Repeat The ACC unit alarm is not functioning. Repair the unit so the alarm will function.
Have the ACC unit serviced or replaced so that the audible or visual alarm is activated when necessary. Correct By: 20-Jun-2022
The following violation(s) have been corrected since the last inspection. |
---|
3701-31-04 (E)(2)(a)(i)/12 ft. non-telescopic reach pole with shepherd's crook is provided 12 ft. non-telescopic reach pole with shepherd's crook was not provided at the unguarded pool. Provide a reach pole with a shepherd's crook. Provide a 12 ft. non-telescopic reach pole in the pool area at all times. Correct By: 13-Jun-2022 |
Comments |
---|
All violations were corrected. Thanks! Pool Notes: 1. The pool water is clear. 2. The pool pH was between 7.6-7.8. 3. The report was emailed to Ms. Lasota. Contact Scott Bradley,R.E.H.S. (732-7614) with any questions. |