Sampling Details | |||
---|---|---|---|
Sub Type: Other | Special Feature: | Location: | |
Area: 1000 | Volume (gallons): 30000 | Flow measure reading (gpm): 0 | Minimum required flow (gpm): 63 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: 676 | Turnover Rate (min): 480 |
Total Chlorine (ppm): 2 | Free Chlorine (ppm): 2 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 110 | Pool water temp ˚F: 82 | pH: 7.5 | Cyanuric acid (ppm): 0 |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): 75 | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(6)(i) / A means of determining rate-of-flow on all water pumps
A means of determining rate-of-flow was not found for the circulation pump. Flow meter has been removed since last inspection.
Properly reinstall a flow meter (10x pipe diameter in straight pipe length upstream from the flow meter and 5x pipe diameter in length of straigh pipe after flow meter) or have a pump curve available for water pump used for the pool.
Comments |
---|
No other violations noted at this time. Water clarity, disinfectant residuals, and water quality readings meet minimum code requirements at this time. Signage and safety equipment provided as required. Restrooms are clean and properly supplied. Pool looks really good at this time. Keep up the good work! |