Sampling Details
Sub Type: Apartment/Condo Special Feature: Location:
Area: 900 Volume (gallons): 25178 Flow measure reading (gpm): 60 Minimum required flow (gpm): 53
Disinfectant: Sodium Hypochlorite Secondary Disinfectant: ORP: 760 Turnover Rate (min): 480
Total Chlorine (ppm): 2.5 Free Chlorine (ppm): 2.5 Combined Chlorine (ppm): 0 Total Bromine (ppm):
Alkalinity (ppm): 80 Pool water temp ˚F: pH: 7.4 Cyanuric acid (ppm):
Spa water temp ˚F: Spa water replaced every 30 days: Max Allow. Filter Flow (gpm): 98 Max Allow. Flow: Jet pump capacity (gpm):
Max Allow. Flow: SF pump capacity (gpm):
[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (D)(7)(c) / Audible/visual alarm shall activate when unit is malfunctioning or when pH or ORP levels are not acceptable.
Critical The ACC unit alarm is not functioning. Repair the unit so the alarm will function.
Have the ACC unit serviced or replaced so that the audible or visual alarm is activated when necessary. Correct By: 13-Jun-2022
3701-31-04 (E)(2)(a)(i) / 12 ft. non-telescopic reach pole with shepherd's crook is provided
12 ft. non-telescopic reach pole with shepherd's crook was not provided at the unguarded pool. Provide a reach pole with a shepherd's crook.
Provide a 12 ft. non-telescopic reach pole in the pool area at all times. Correct By: 13-Jun-2022


Inspection Information


[?] Facility Type: Pool

[?] Inspection Type: Standard

[?] Inspection Date: 10-June-2022

Comments
Pool Notes:
1. The pool water is clear.
2. ACC unit pH noted at 7.5.
3. Pool turnover rate=7.0 hours.
4. Please test, then record periodic testing of the ACC unit.
5. The report was emailed to Ms. Lasota.
Contact Scott Bradley,R.E.H.S. (732-7614) with any questions.