Sampling Details | |||
---|---|---|---|
Sub Type: Hotel/motel | Special Feature: | Location: | |
Area: 490 | Volume (gallons): 12795 | Flow measure reading (gpm): 50 | Minimum required flow (gpm): 27 |
Disinfectant: Salt | Secondary Disinfectant: | ORP: 725 | Turnover Rate (min): 310 |
Total Chlorine (ppm): 5 | Free Chlorine (ppm): 5 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 70 | Pool water temp ˚F: 80 | pH: 7.2 | Cyanuric acid (ppm): 0 |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
No critical violations were documented at the time of inspection.
No violations were documented at the time of inspection.
Comments |
---|
The disinfectant residuals and water quality parameters meet code requirement. The recommended range is 2-4 ppm. Make sure the free chlorine stays above 1.0 ppm. -pH was measured at 7.2. -All required safety equipment was provided. -The pool perimeter was secure. -The filter pressure was 12 psi on both filters. -Turn over rate was 310 minutes. - The facility uses salt and acid to create chlorine. Therefore the pool is disinfected using chlorine. - ACC tests recorded monthly. Thanks. - Pool records properly recorded. - ORP at 725mv, pH on ACC at 7.22. No violations noted. Keep up the good work. If you have any questions or concerns, call Bela Perler at 513-732-7612. |