Sampling Details | |||
---|---|---|---|
Sub Type: Other | Special Feature: | Location: | |
Area: 1650 | Volume (gallons): 51000 | Flow measure reading (gpm): 120 | Minimum required flow (gpm): 110 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: 720 | Turnover Rate (min): 480 |
Total Chlorine (ppm): 5 | Free Chlorine (ppm): 5 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 80 | Pool water temp ˚F: 76 | pH: 7.4 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): 141 | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(4)(a)(iv) / Water temperatures are recorded daily
Repeat Water temperatures were not being recorded daily.
Take and record the water temperature at least once/day. 3701-31-04 (B)(4)(c) / SVRS/APSOS/ACC test results/ service records are maintained
Repeat Required monthly APSOS/ACC test results were not recorded.
The test results & service records for these devices must be kept on site for review. If the device has not been recently tested, have the device tested immediately and provide documentation of the test results. ACC/ APSOS was tested by this inspector during inspection and found to be functioning properly. Test was recorded in pool records. 3701-31-04 (D)(7)(d) / Flow or pressure switch with a shut off valve shall be provided and tested monthly.
Critical Repeat Corrected During Inspection Flow or pressure switch for a shut off valve was tested monthly as required.
Have the ACC unit tested to verify it functions properly. Provide records indicating that the unit is being tested monthly. Inspector tested ACC during inspection and found it to be functioning properly.
Comments |
---|
Facility inspection notes: Water clarity, disinfectant residuals, and water quality readings meet minimum code requirements at this time. Cyanuric acid reading <30 ppm. Result was not recorded in the section above because the report program does not allow special characters such as ">". Signage and safety equipment provided as required. Restrooms are clean and supplied. |