Sampling Details | |||
---|---|---|---|
Sub Type: Camp | Special Feature: | Location: | |
Area: 1350 | Volume (gallons): 25000 | Flow measure reading (gpm): 40 | Minimum required flow (gpm): 62 |
Disinfectant: | Secondary Disinfectant: | ORP: | Turnover Rate (min): 480 |
Total Chlorine (ppm): 3 | Free Chlorine (ppm): 3 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): | Pool water temp ˚F: | pH: 7.2 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(6)(c) / Cross connection hazards shall be prevented.
Repeat Gutter was tied to backwash line from filter.
Remove all cross connection hazards from the pool area. 3701-31-04 (B)(6)(f) / Required turnover rates are sufficient
Repeat Required turnover rates were not met.
Have the circulation system evaluated to determine why the turnover rates are not able to be met. Once the reasons have been determined have the issue repaired. If necessary, submit plans to the Ohio Department of Health to review and approve. 3701-31-04 (B)(6)(j) / All SVRS devices are maintained/ functional and tested
Critical Repeat SVRS device was not tested in accordance with the manufacturer's specifications.
Have the SVRS device tested immediately and maintain the test results on site.
The following violation(s) have been corrected since the last inspection. |
---|
3701-31-04 (B)(4)(a)(i)/Disinfection residuals are tested daily at pool side at required intervals for pools/automatic chemical controllers/special features Disinfection residuals were not tested daily at pool side and/or at the required intervals for pools/automatic chemical controllers/special features. ACC not in use. Test the disinfection residual every day before bathers enter the water. Disinfection residual must then be tested every 4 hours when an ACC is not in use. If an ACC is in use the disinfectant residual must be tested every 12 hours while the pool is in use. |
3701-31-04 (B)(4)(a)(ii)/Combined chlorine is tested daily at pool side prior to use Combined chlorine was not tested daily at pool side prior to use and every 4 hours afterwards. ACC not in use. Test for combined chlorine prior to bathers entering the water and every 4 hours the pool is open for use. If ACC is in use combined chlorine must be tested every 12 hours while the pool is in use. |
3701-31-04 (B)(4)(a)(iii)/pH is tested daily at pool side at required intervals for pools/automatic chemical controllers/special features pH was not tested daily at pool side and/or at required intervals for pools/automatic chemical controllers/special features. ACC not in use. pH must be tested prior to bathers entering the water and every 4 hours the pool is open for use. If ACC is in use pH must be tested every 12 hours while the pool is in use. |
3701-31-04 (B)(6)(c)(i)/Backflow prevention devices shall be maintained. No backflow prevention device was provided on fill hose. Provide appropriate backflow prevention device on fill hose. |
3701-31-04 (D)(7)(d)/Flow or pressure switch with a shut off valve shall be provided and tested monthly. Flow or pressure switch for a shut off valve was not tested monthly Provide records indicating that the unit is being tested monthly. |
3701-31-04 (B)(6)(o)/Ladders/stairs/steps are in good repair/slip resistent Railing into pool was loose. Repair such that railing is secure. |
Comments |
---|
Test SVRS device immediately and record results. |