Sampling Details
Sub Type: Apartment/Condo Special Feature: Location:
Area: 985 Volume (gallons): 29500 Flow measure reading (gpm): 110 Minimum required flow (gpm): 61
Disinfectant: Sodium Hypochlorite Secondary Disinfectant: ORP: Turnover Rate (min): 480
Total Chlorine (ppm): 10 Free Chlorine (ppm): 10 Combined Chlorine (ppm): 0 Total Bromine (ppm):
Alkalinity (ppm): Pool water temp ˚F: 75 pH: 7.8 Cyanuric acid (ppm):
Spa water temp ˚F: Spa water replaced every 30 days: Max Allow. Filter Flow (gpm): 98 Max Allow. Flow: Jet pump capacity (gpm):
Max Allow. Flow: SF pump capacity (gpm):
[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat The weir is missing from the 3' end skimmer.
Replace the missing weir. Correct By: 16-Jun-2016
3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
After twelve (12) drops of solution #9, the Alkalinity Test Solution turned yellow.
Lower the free chlorine level so pool Alkalinity readings can be determined accurately. Correct By: 16-Jun-2016
3701-31-04 (E)(2)(d) / First aid kit provided
First aid equipment was not provided.
Provide a first aid kit. Correct By: 16-Jun-2016
3701-31-04 (E)(2)(e) / Working emergency telephone/call box provided.
Emergency device (telephone) was not working.
Repair the phone so it can be used in emergencies. Correct By: 16-Jun-2016


Inspection Information


[?] Facility Type: Pool

[?] Inspection Type: Standard

[?] Inspection Date: 08-June-2016

Comments
Pool Notes:
1. The pool water is clear.
2. Pool turnover rate=4.5 hours.
3. Filter pressure gauge noted at 10psi.
4. The 2016 Swimming Pool License is posted.
5. Copy of the inspection report was left in the filter room door.