Sampling Details | |||
---|---|---|---|
Sub Type: Hotel/motel | Special Feature: | Location: | |
Area: 418 | Volume (gallons): 12500 | Flow measure reading (gpm): 45 | Minimum required flow (gpm): 26 |
Disinfectant: Salt | Secondary Disinfectant: | ORP: 765 | Turnover Rate (min): 480 |
Total Chlorine (ppm): 1.6 | Free Chlorine (ppm): 0.4 | Combined Chlorine (ppm): 1.2 | Total Bromine (ppm): |
Alkalinity (ppm): 100 | Pool water temp ˚F: 82 | pH: 7.6 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): 120 | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(4) / The licensee /authorized representative is keeping records
Repeat The licensee /authorized representative was not keeping or maintaining operational records. Observed no testing records for day of inspection or previous two days.
All facility records must be maintained and available for review upon request. Ensure water testing results/records are recorded and maintained at the required frequency. 3701-31-04 (E)(2)(d) / First aid kit provided
Repeat First aid equipment was not provided. Observed no disposable gloves in the first aid kit. Ensure first aid kit is properly supplied with disposable gloves, gauze and bandages.
Provide first aid equipment, including a first aid kit, at the pool at all times. 3701-31-04(D)(6)(a)(2) / Pool free chlorine disinfectant residual shall be above 1 ppm.
Critical Repeat Pool free chlorine disinfectant residual was below 1 ppm. Observed 0.4 ppm free chlorine. Ensure free chlorine disinfectant residual is at 1 ppm or above.
Do not operate the pool until the chlorine disinfectant residual is at 1 ppm or above. Operator voluntarily closed pool. Will follow-up.
Comments |
---|
Inspection Notes: --Free chlorine disinfectant residual below 1 ppm. Operator voluntarily closed the pool to bathers at time of inspection. Recommend pool remain closed to bathers until disinfectant residual is 1 ppm or above. Will follow-up. --Please submit certificates of compliance along with make and model information and expiration dates for pool main drain covers. |