Sampling Details | |||
---|---|---|---|
Sub Type: Other | Special Feature: | Location: | |
Area: 1800 | Volume (gallons): 54000 | Flow measure reading (gpm): 120 | Minimum required flow (gpm): 113 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: 733 | Turnover Rate (min): 480 |
Total Chlorine (ppm): 6 | Free Chlorine (ppm): 6 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 90 | Pool water temp ˚F: 78 | pH: 7.6 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): 74 | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical Repeat Specifications could not be located for the main drain cover.
Provide specifications for the main drain cover to verify VGB compliance. 3701-31-04 (B)(6)(h) / Required meters and gauges maintained/functional
Repeat One (1) filter pressure gauge does not appear to be working.
Repair or replace the gauge so filter pressures can be monitored accurately. 3701-31-04 (B)(6)(h) / Required meters and gauges maintained/functional
Weirs are missing from the skimmer baskets.
Replace the missing weirs. 3701-31-04 (B)(6)(k) / Outlet drain covers are secure/meet ANSI/ASME A112.19.8-2007 requirements.
Critical Repeat Specifications were not available for the main drain cover.
Provide specifications for the main drain cover to verify VGB compliance.
Comments |
---|
No other violations observed during the inspection. The pool otherwise looks great! Pool Notes: 1. The 2017 pool license is posted. 2. The pool water is clear. 3. Proper safety equipment is available for use. 4. ACC unit and SVRS device testing is documented in the pool records. 5. Pool turnover rate=7.5 hours. 6. ACC unit pH noted at 7.5. 7. One (1) filter pressure gauge was noted at 54psi. It is recommended this filter be backwashed. 8. The report was emailed to Ms. Michelson. Inspection conducted by Scott Bradley,R.S. 732-7614 |