Sampling Details | |||
---|---|---|---|
Sub Type: Apartment/Condo | Special Feature: | Location: | |
Area: 880 | Volume (gallons): 26400 | Flow measure reading (gpm): 80 | Minimum required flow (gpm): 63 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: | Turnover Rate (min): 480 |
Total Chlorine (ppm): 7 | Free Chlorine (ppm): 7 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 100 | Pool water temp ˚F: 79 | pH: 7.5 | Cyanuric acid (ppm): 0 |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (A) / All construction or alterations of a public swimming pool are approved
Repeat The installation of the "Stingl" switch could not be determined to be approved.
An equipment replacement notification report was given to the operator. Submit the form to ODH for approval and keep for records. 3701-31-04 (B)(4)(c) / SVRS/APSOS/ACC test results/ service records are maintained
SVRS test results/ service records were not maintained.
The test results/service records for these devices must be kept on site for review. If the device has not been recently serviced, have the device tested immediately and provide documentation of the test results. 3701-31-04 (B)(6)(c)(v) / Discharge of water from a public swimming pool shall be in accordance with OEPA.
Water from the pool was not being discharged to a sanitary sewage system. It is discharged outside to a gravel bed.
Provide documentation that the method of water discharge is approved by the OEPA. 3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
The gate near the pump room is not self latching.
The gate was locked. The gate is going to stay locked until it is self latching. 3701-31-04 (E)(2)(a)(i) / 12 ft. non-telescopic reach pole with shepherd's crook is provided
The 12 ft. reach pole with shepherd's crook is telescopic.
Ensure the pole is non-telescoping.
Comments |
---|
-The disinfectant residuals and water quality parameters meet code requirement. -Free chlorine was 7 ppm, ideal range is 1-2 ppm. -All required safety equipment was provided. See violations for shepherd crook. -The pool perimeter was secure. See violations for gate. -The filter pressure was 9 psi. -The pool water is clear. -Turn over rate was 5.5 hours. If you have any questions or concerns, call me at (513) 732-7612. |