Sampling Details
Sub Type: Apartment/Condo Special Feature: Location:
Area: 985 Volume (gallons): 29500 Flow measure reading (gpm): 100 Minimum required flow (gpm): 61
Disinfectant: Sodium Hypochlorite Secondary Disinfectant: ORP: 610 Turnover Rate (min): 480
Total Chlorine (ppm): 1 Free Chlorine (ppm): 1 Combined Chlorine (ppm): 0 Total Bromine (ppm):
Alkalinity (ppm): 80 Pool water temp ˚F: pH: 7.8 Cyanuric acid (ppm):
Spa water temp ˚F: Spa water replaced every 30 days: Max Allow. Filter Flow (gpm): 98 Max Allow. Flow: Jet pump capacity (gpm):
Max Allow. Flow: SF pump capacity (gpm):
[?] A summary of the violations found during the inspection are listed below.

3701-31-04 ( D )(6)(a) / ORP reading shall be 650 millivolts or greater.
The ACC unit ORP reading was noted at 610mv.
Increase and maintain the ACC unit ORP at 650mv minimum.
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat The weir is missing from the 3' end skimmer.
Replace the missing weir. Correct By: 16-Jun-2016


Inspection Information


[?] Facility Type: Pool

[?] Inspection Type: Follow-up

[?] Inspection Date: 17-June-2016

The following violation(s) have been corrected since the last inspection.
3701-31-04 (E)(2)(d)/First aid kit provided
First aid equipment was not provided.
Provide a first aid kit. Correct By: 16-Jun-2016
3701-31-04 (E)(2)(e)/Working emergency telephone/call box provided.
Emergency device (telephone) was not working.
Repair the phone so it can be used in emergencies. Correct By: 16-Jun-2016
3701-31-04 (C)(3)/Total alkalinity is at or greater than 60 ppm
After twelve (12) drops of solution #9, the Alkalinity Test Solution turned yellow.
Lower the free chlorine level so pool Alkalinity readings can be determined accurately. Correct By: 16-Jun-2016
Comments
All other violations corrected.
Thanks!
Pool Notes:
1. The pool water is clear.
2. Pool turnover rate=4.9 hours.
3. Record monthly ACC unit alarm testing on the provided Weekly Operational report.
4. A representative from Cincy Pool Management arrived at the pool during the inspection and was made aware of the 1.0ppm free chlorine residual, and the ACC unit ORP.
5. The 2016 Swimming Pool License is posted.
6. The report was emailed to Mr. Blume.
7. The reinspection scheduled for 6/16/16 was rescheduled.
Inspection conducted by Scott Bradley,R.S. 732-7614