Sampling Details | |||
---|---|---|---|
Sub Type: Other | Special Feature: | Location: | |
Area: 1800 | Volume (gallons): 54000 | Flow measure reading (gpm): 120 | Minimum required flow (gpm): 113 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: 658 | Turnover Rate (min): 480 |
Total Chlorine (ppm): 6 | Free Chlorine (ppm): 6 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 80 | Pool water temp ˚F: 83 | pH: 7.4 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): 74 | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical Repeat Specifications are not available for the one (1) main drain cover.
Provide specifications for the main drain cover to verify VGB compliance. 3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat One (1) 3' end skimmer basket weir is missing.
Replace the missing weir. 3701-31-04 (B)(6)(h) / Required meters and gauges maintained/functional
Repeat One (1) filter pressure gauge is not working.
Repair the gauge so the filter pressure can be monitored. 3701-31-04 (B)(6)(k) / Outlet drain covers are secure/meet ANSI/ASME A112.19.8-2007 requirements.
Critical Repeat Specifications for the one (1) main drain cover is not available.
Provide specifications for the main drain cover to verify VGB compliance. 3701-31-04 (B)(6)(q) / Depth markers/deck warning signs are maintained
Repeat All depth markers are faded.
Prior to the start of the 2017 Pool Season, repaint all depth markers.
Comments |
---|
No other violations observed during the inspection. The pool otherwise looks great! Pool Notes: 1. The 2016 pool license is posted. 2. The pool water is clear. 3. Proper safety equipment is available for use. 4. ACC unit testing is documented in the pool records. 5. Pool turnover rate=7.5 hours. 6. It is recommend the filter with a 55psi pressure gauge reading be backwashed. 7. The report was emailed to Ms. Michelson. Inspection conducted by Scott Bradley,R.S. 732-7614 |