Sampling Details | |||
---|---|---|---|
Sub Type: Other | Special Feature: | Location: | |
Area: 1160 | Volume (gallons): 35500 | Flow measure reading (gpm): 95 | Minimum required flow (gpm): |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: 685 | Turnover Rate (min): |
Total Chlorine (ppm): 6 | Free Chlorine (ppm): 6 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 90 | Pool water temp ˚F: 80 | pH: 7.8 | Cyanuric acid (ppm): 15 |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(4)(a)(vii) / Cyanuric acid is tested weekly
Cyanuric acid was not tested weekly.
Test for cyanuric acid level at least once/week. 3701-31-04 (D)(8) / Acceptable test kit provided/adequate/in good repair
The test kit provided did not contain reagent #3.
Obtain a test kit that can properly measure all the required water quality parameters.
Comments |
---|
Pool water is clear. Disinfectant residuals meet minimum code requirements at this time. Safety equipment provided. Emergency phone functioning during the time of inspection. First Aid kit was supplied and appropriate warning signs were posted. Records look good. Keep up the good work! |