Sampling Details | |||
---|---|---|---|
Sub Type: Other | Special Feature: | Location: | |
Area: 3200 | Volume (gallons): 137500 | Flow measure reading (gpm): 425 | Minimum required flow (gpm): 287 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: | Turnover Rate (min): 480 |
Total Chlorine (ppm): 5 | Free Chlorine (ppm): 5 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 90 | Pool water temp ˚F: 78 | pH: 7.6 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical Corrected During Inspection Equalizer lines were not plugged.
PIC properly plugged the equalizer lines. 3701-31-04 (B)(6)(o) / Ladders/stairs/steps are in good repair/slip resistent
Repeat The hand rail was not secured.
Repair the hand rail so that it is secure. 3701-31-04 (B)(6)(q) / Depth markers/deck warning signs are maintained
Repeat Depth markers were not observed on the pool deck.
Add depth markers to the pool deck.
Comments |
---|
1. Water clarity and disinfectant residuals meet minimum code requirements. 2. Safety equipment provided as required. 3. Pool perimeter was secure 4. Filters psi were 10/11/8/13 |