Sampling Details
Sub Type: Apartment/Condo Special Feature: Location:
Area: 985 Volume (gallons): 29500 Flow measure reading (gpm): 40 Minimum required flow (gpm): 61
Disinfectant: Sodium Hypochlorite Secondary Disinfectant: ORP: 745 Turnover Rate (min): 480
Total Chlorine (ppm): 3 Free Chlorine (ppm): 3 Combined Chlorine (ppm): 0 Total Bromine (ppm):
Alkalinity (ppm): 90 Pool water temp ˚F: 78 pH: 7.4 Cyanuric acid (ppm):
Spa water temp ˚F: Spa water replaced every 30 days: Max Allow. Filter Flow (gpm): 98 Max Allow. Flow: Jet pump capacity (gpm):
Max Allow. Flow: SF pump capacity (gpm):
[?] A summary of the violations found during the inspection are listed below.

No critical violations were documented at the time of inspection.

No violations were documented at the time of inspection.


Inspection Information


[?] Facility Type: Pool

[?] Inspection Type: Standard

[?] Inspection Date: 07-June-2018

Comments
No violations observed during the inspection.
The pool otherwise Looks Great!
Pool Notes:
1. The pool water is clear.
2. ACC unit pH noted at 7.6.
3. ACC alarm functions when tested.
4. All required safety equipment is available.
5. Document periodic ACC and SVRS device testing in the pool records.
6. Pool turnover rate=12.3 hours. It is recommended the pool filter system flow rate be increased to 61 to maintain an eight (8) hour turnover rate.
7. The report was emailed to Mr. Sinkovich.
Contact Scott Bradley,R.S. (732-7614) with any questions.