Sampling Details | |||
---|---|---|---|
Sub Type: Other | Special Feature: | Location: | |
Area: 1696 | Volume (gallons): 52000 | Flow measure reading (gpm): 110 | Minimum required flow (gpm): 109 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: 810 | Turnover Rate (min): 480 |
Total Chlorine (ppm): 1 | Free Chlorine (ppm): 1 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 80 | Pool water temp ˚F: 76 | pH: 7.3 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): 74 | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (A)(1) / Public swimming pool is licensed
Repeat The swimming pool license could not be located.
Post the 2018 Swimming Pool license.
3701-31-04 (B)(1)(a) / Outlet covers shall be installed/secured/in compliance
Critical Repeat The two (2) main drain covers needed to be replaced in 2012.
Replace the main drain covers to verify VGB compliance.
3701-31-04 (B)(6)(k) / Outlet drain covers are secure/meet ANSI/ASME A112.19.8-2007 requirements.
Critical Repeat The two (2) main drain covers needed to replaced in 2012.
Replace the main drain covers to verify VGB compliance.
3701-31-04 (D)(7)(c) / Audible/visual alarm shall activate when unit is malfunctioning or when pH or ORP levels are not acceptable.
Critical Repeat The ACC unit would not function when tested.
Have the ACC unit serviced so the alarm will function when tested. Correct By: 06-Jul-2018
Comments |
---|
No other violations observed during the inspection. The pool otherwise Looks Great! Pool Notes: 1. Document periodic ACC unit alarm testing in pool records. 2. The pool water is clear. 3. Proper safety equipment is available for use. 4. The pool pH was between 7.2-7.4. 5. ACC unit pH noted at 7.5. 6. Pool turnover rate=7.9 hours. 7. Filter pressure gauges noted at 15 and 16psi. 8. The report was emailed to Mr. Hooker. Contact Scott Bradley,R.S. (732-7614) with any questions. |