Sampling Details | |||
---|---|---|---|
Sub Type: Other | Special Feature: | Location: | |
Area: 1440 | Volume (gallons): 43200 | Flow measure reading (gpm): 100 | Minimum required flow (gpm): 90 |
Disinfectant: | Secondary Disinfectant: | ORP: 755 | Turnover Rate (min): |
Total Chlorine (ppm): 2.5 | Free Chlorine (ppm): 2.5 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 150 | Pool water temp ˚F: 80 | pH: 7.6 | Cyanuric acid (ppm): 0 |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (A) / All construction or alterations of a public swimming pool are approved
Equipment change since last inspection.
Pump: From WhisperFlo model WFE-8C to WhisperFloXF model XF-12
Chemical feeder: From Flex Flo model A1N20A-6T to Flex Flo model A1N30A-6T
ACC: From Aqua Sol model 6009A to Hayward CAT 2000
pH feeder: From Aqua Sol model 45MP3 to Flex Flo A1N00A6T
If you have not already done so, please submit an Equipment Replacement Notification Report.
3701-31-04 (B)(4)(a)(ii) / Combined chlorine is tested daily at pool side prior to use
Repeat Combined chlorine was not tested daily at pool side prior to use.
Test for combined chlorine prior to bathers entering the water and every 4 hours the pool is open for use. If ACC is in use combined chlorine must be tested every 12 hours while the pool is in use. For spraygrounds and spray features, the combined chlorine must be tested at 1 spray feature every 6 hours the sprayground or spray feature is in use.
3701-31-04 (B)(4)(a)(vii) / Cyanuric acid is tested weekly
Repeat Cyanuric acid was not tested weekly.
Test for cyanuric acid level at least once/week.
3701-31-04 (B)(6)(s) / Perimeter barrier is in good repair to prevent unauthorized entry
Repeat Corrected During Inspection Gates or doors were not self-closing and lockable.
Repair gates or doors in order to be self-closing and lockable.
3701-31-04 (D)(8) / Acceptable test kit provided/adequate/in good repair
No reagent present for testing cyanuric acid.
Purchase cyanuric acid reagent to perform weekly testing.
3701-31-04 (E)(2)(d) / First aid kit provided
Repeat First aid equipment was not provided.
Provide first aid equipment, including a first aid kit, at the pool at all times.
Comments |
---|
Water is clear and disinfectant residuals meet minimum code requirements at this time. All signs and safety equipment were visible and accessible. Please replace first aid kit. Acid feeding container observed to be empty during time of inspection. Pool operator arrived and was informed. Please post new pool license for 2020. ACC was tested during inspection and functioning properly. Pool looks great! Keep up the great work. |