Sampling Details | |||
---|---|---|---|
Sub Type: Apartment/Condo | Special Feature: | Location: | |
Area: 985 | Volume (gallons): 29500 | Flow measure reading (gpm): 100 | Minimum required flow (gpm): 61 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: 715 | Turnover Rate (min): 480 |
Total Chlorine (ppm): 3 | Free Chlorine (ppm): 3 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 60 | Pool water temp ˚F: 83 | pH: 7.4 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): 98 | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat One (1) 3' end skimmer basket weir is missing.
Replace the missing weir.
Comments |
---|
No other violations observed during the inspection. The pool otherwise Looks Great! Pool Notes: 1. The pool water is clear. 2. Pool turnover rate=4.9 hours. 3. Filter pressure gauge noted at 10psi. 4. ACC unit alarm functioned when tested. Unit testing is documented in the pool records. 5. ACC unit pH noted at 7.6. 6. The 2016 Swimming Pool License is posted. 7. The report was emailed to Mr. Blume. Inspection conducted by Scott Bradley,R.S. 732-7614 |