Sampling Details | |||
---|---|---|---|
Sub Type: Apartment/Condo | Special Feature: | Location: | |
Area: 750 | Volume (gallons): 22500 | Flow measure reading (gpm): 60 | Minimum required flow (gpm): 47 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: | Turnover Rate (min): 480 |
Total Chlorine (ppm): 6 | Free Chlorine (ppm): 6 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 140 | Pool water temp ˚F: 81 | pH: 8.2 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): 120 | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(6)(h) / Required meters and gauges maintained/functional
Repeat Weirs are missing from the skimmers. Replace the missing weirs.
Maintain all meters and gauges in a properly functioning manner at all times while the pool is in operation. 3701-31-04 (C)(2) / pH is within 7.2 to 7.8
Repeat The pool pH was noted at 8.2 (2 drops of acid demand lowered the pH to 7.6). Lower the pH to between 7.2-7.8.
Treat the pool water so that the pH is within the acceptable range.
Comments |
---|
No other violations observed during the inspection. The pool otherwise looks great! Pool Notes: 1. Pressure gauge noted at 12psi. 2. Turnover rate=6.25 hours. 3. The pool water is clear. 4. All required safety equipment is available. 5. The report was emailed to the facility. Contact Scott Bradley,R.E.H.S. (732-7614) with any questions. |