Sampling Details | |||
---|---|---|---|
Sub Type: Other | Special Feature: | Location: | |
Area: 1160 | Volume (gallons): 35500 | Flow measure reading (gpm): 50 | Minimum required flow (gpm): |
Disinfectant: | Secondary Disinfectant: | ORP: 780 | Turnover Rate (min): 710 |
Total Chlorine (ppm): 5 | Free Chlorine (ppm): 5 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 60 | Pool water temp ˚F: 80 | pH: 6.9 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(6)(f) / Required turnover rates are sufficient
Required turnover rates were not met.
Have the circulation system evaluated to determine why the turnover rates are not able to be met. Once the reasons have been determined have the issue repaired. If necessary, submit plans to the Ohio Department of Health to review and approve. 3701-31-04 (C)(2) / pH is within 7.2 to 7.8
pH was outside the range of 7.2 to 7.8. Observed to be 6.9
Treat the pool water so that the pH is within the acceptable range. 3701-31-04 (E)(3)(a) / "WARNING, NO LIFEGUARD", sign posted
Corrected During Inspection The unguarded pool was in use without the "WARNING, NO LIFEGUARD" sign posted.
Post the WARNING, NO LIFEGUARD sign in a conspicuos location at all times the pool is available for use.
Comments |
---|
Chlorine and alkalinity meet requirements. pH was low at 6.9. There was no WARNING-NO LIFEGUARD ON DUTY sign. Sign was put up during inspection. A better method of hanging the sign is recommended. |