Sampling Details | |||
---|---|---|---|
Sub Type: Other | Special Feature: | Location: | |
Area: 1840 | Volume (gallons): 62400 | Flow measure reading (gpm): 200 | Minimum required flow (gpm): 130 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: | Turnover Rate (min): 312 |
Total Chlorine (ppm): 8 | Free Chlorine (ppm): 8 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 110 | Pool water temp ˚F: 67 | pH: 7.8 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(1)(e) / Automatic Chemical Controller (ACC) shall function properly.
Critical Automatic Chemical Controller (ACC) was not functioning properly at the time of the inspection. ACC unit was noted to be flashing high pH/low HRR/Cl/Br lockout at time of inspection. Water chemistry noted to be within the required parameters. Contacted pool operator and discussed status of ACC, and per pool operator, unit is to be replaced.
Do not operate the pool when the ACC unit is not functioning properly. Ensure that the ACC unit is functioning properly prior to placing the pool back into operation. Correct By: 22-Jun-2023 3701-31-04 (B)(6)(y) / Chemicals are properly stored/used
Critical Acid stored next to pool chlorinator. Ensure that chemicals are separated.
Label and properly store all chemical containers to avoid a chemical reaction or unnecessary exposure. Correct By: 22-Jun-2023
Comments |
---|
Proper safety equipment observed in pool area. ACC unit not functioning properly; discussed status with pool operator, and unit is to be replaced. Ensure unit is functional and replaced. Recommend water chemistry is performed every four hours until ACC unit issue is resolved. |