Sampling Details
Sub Type: Apartment/Condo Special Feature: Location:
Area: 1615 Volume (gallons): 63447 Flow measure reading (gpm): 132 Minimum required flow (gpm): 132
Disinfectant: Sodium Hypochlorite Secondary Disinfectant: ORP: Turnover Rate (min): 480
Total Chlorine (ppm): 8 Free Chlorine (ppm): 8 Combined Chlorine (ppm): 0 Total Bromine (ppm):
Alkalinity (ppm): 90 Pool water temp ˚F: 83 pH: 7.6 Cyanuric acid (ppm): 0
Spa water temp ˚F: Spa water replaced every 30 days: Max Allow. Filter Flow (gpm): 98 Max Allow. Flow: Jet pump capacity (gpm):
Max Allow. Flow: SF pump capacity (gpm):
[?] A summary of the violations found during the inspection are listed below.

3701-31-04 (B)(4)(a)(vi) / Total alkalinity is tested weekly
Repeat Total alkalinity was not tested weekly.
Test total alkalinity at least once/week.
3701-31-04 (B)(4)(c) / SVRS/APSOS/ACC test results/ service records are maintained
Repeat SVRS test results were not maintained.
Test the SVRS to ensure it functions properly and record the results.
3701-31-04 (B)(6) / Equipment is maintained per manufacturers specifications.
Repeat All skimmer weirs were missing.
Replace missing skimmer weirs.


Inspection Information


[?] Facility Type: Pool

[?] Inspection Type: Standard

[?] Inspection Date: 09-August-2016

Comments
-The disinfectant residuals and water quality parameters meet code requirement.
-Free chlorine was measured at 8 ppm. The ideal range is 2-4 ppm.
-All required safety equipment was provided.
-The pool perimeter was secure.
-The filter pressure was 12/15 psi.
-The pool water was clear.
-The Stingl switch was functioning correctly.
-Turn over rate was 480 minutes.