Sampling Details | |||
---|---|---|---|
Sub Type: Hotel/motel | Special Feature: | Location: | |
Area: 418 | Volume (gallons): 12500 | Flow measure reading (gpm): 45 | Minimum required flow (gpm): 26 |
Disinfectant: Salt | Secondary Disinfectant: | ORP: 705 | Turnover Rate (min): 480 |
Total Chlorine (ppm): 2.5 | Free Chlorine (ppm): 1.5 | Combined Chlorine (ppm): 1 | Total Bromine (ppm): |
Alkalinity (ppm): 130 | Pool water temp ˚F: 82 | pH: 7.8 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): 120 | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(4) / The licensee /authorized representative is keeping records
Repeat The licensee /authorized representative was not keeping or maintaining operational records. Observed last water chemistry test results in log to be from Wednesday, January 12th. Ensure water chemistry testing results are maintained at the required frequency. Ensure disinfectant and pH are measured and recorded before opening and every 12 hours for pools with an ACC. Ensure water temperature is measured once daily. Ensure alkalinity is measured at least once weekly. Records are to be kept for two years.
All facility records must be maintained and available for review upon request. 3701-31-04 (E)(2)(d) / First aid kit provided
Repeat Observed first aid kit not properly supplied with gloves. Ensure first aid kit is properly supplied with a minimum of gauze, bandages and gloves.
Provide first aid equipment, including a first aid kit, at the pool at all times.
The following violation(s) have been corrected since the last inspection. |
---|
3701-31-04 (B)(6)/Equipment is maintained per manufacturers specifications. Equipment was not maintained per manufacturers specifications. Observed the pressure gauge on the cartridge filter indicating filter is due for cleaning. Ensure manufacturer's directions are followed and manually clean filter and inspect for tears or holes. All equipment must be maintained in accordance with the manufacturers specifications. |
3701-31-04 (C)(2)/pH is within 7.2 to 7.8 pH was outside the range of 7.2 to 7.8. Observed the pool water pH to be 7.1. Treat the pool water so that the pH is within the acceptable range. |
3701-31-04 (D)(7)(c)/Audible/visual alarm shall activate when unit is malfunctioning or when pH or ORP levels are not acceptable. The ACC unit was not activating an audible or visual alarm when unit malfunctioned or when pH or ORP levels were not acceptable. Observed the ACC indicating a "no flow" alarm. Unable to read chlorine and ORP. Ensure flow is adequate and ACC is serviced or replaced. Will follow-up. |
3701-31-04(D)(6)(a)(2)/Pool free chlorine disinfectant residual shall be above 1 ppm. Pool free chlorine disinfectant residual was below 1 ppm. Observed the pool free chlorine residual to be 0.0 ppm. Do not operate the pool until the chlorine disinfectant residual is at 1 ppm or above. Will follow-up. |
Comments |
---|
--Observed 1.5 ppm free chlorine residual at time of inspection. --"Low flow" alarm on ACC resolved--ACC reading pH and ORP at time of inspection. --Please submit certificates of compliance with expiration dates for pool main drain covers and equalizer line covers or replace. --pH measured at 7.8. --Was informed cartridge filters were manually cleaned and inspection. PSI observed to be 27 and within acceptable range on gauge. |