Sampling Details | |||
---|---|---|---|
Sub Type: School | Special Feature: | Location: | |
Area: 1800 | Volume (gallons): 65000 | Flow measure reading (gpm): | Minimum required flow (gpm): 135 |
Disinfectant: Sodium Hypochlorite | Secondary Disinfectant: | ORP: 790 | Turnover Rate (min): 480 |
Total Chlorine (ppm): 3 | Free Chlorine (ppm): 3 | Combined Chlorine (ppm): 0 | Total Bromine (ppm): |
Alkalinity (ppm): 50 | Pool water temp ˚F: 87 | pH: 7.5 | Cyanuric acid (ppm): 0 |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(4)(c) / SVRS/APSOS/ACC test results/ service records are maintained
Repeat Monthly ACC test results were not maintained.
The test results & service records for these devices must be kept on site for review. If the device has not been recently serviced, have the device tested immediately and provide documentation of the test results. 3701-31-04 (C)(3) / Total alkalinity is at or greater than 60 ppm
Repeat Total alkalinity was less than 60 ppm.
Raise the total alkalinity to at least 60 ppm.
Comments |
---|
Pool inspection notes: Disinfectant residual and pH readings meet minimum code requirements at this time. Water clarity is excellent. Pool has two (2) large unblockable custom fabricated drains in the deep end of the pool. Recommend replacing pool reagents annually (mark received by date on reagents or kit to keep track). ACC tested during inspection. Visual no flow alarm activated; chemical feed pumps deactivated as required. Pool looks great! |