Sampling Details | |||
---|---|---|---|
Sub Type: Hotel/motel | Special Feature: | Location: | |
Area: 490 | Volume (gallons): 12795 | Flow measure reading (gpm): | Minimum required flow (gpm): |
Disinfectant: | Secondary Disinfectant: | ORP: | Turnover Rate (min): |
Total Chlorine (ppm): | Free Chlorine (ppm): 7 | Combined Chlorine (ppm): | Total Bromine (ppm): |
Alkalinity (ppm): | Pool water temp ˚F: | pH: 8.0 | Cyanuric acid (ppm): |
Spa water temp ˚F: | Spa water replaced every 30 days: | Max Allow. Filter Flow (gpm): | Max Allow. Flow: Jet pump capacity (gpm): |
Max Allow. Flow: SF pump capacity (gpm): |
3701-31-04 (B)(4)(c) / SVRS/APSOS/ACC test results/ service records are maintained
Repeat SVRS device and ACC unit test results were not recorded. Record periodic testing in records.
The test results/service records for these devices must be kept on site for review. If the device has not been recently serviced, have the device tested immediately and provide documentation of the test results. Correct By: 07-Oct-2022 3701-31-04 (B)(6)(j) / All SVRS devices are maintained/ functional and tested
Critical Repeat Periodic SVRS testing could not be verified. Record periodic SVRS device testing.
Correct By: 07-Oct-2022 3701-31-04 (C)(2) / pH is within 7.2 to 7.8
Repeat The pool pH was noted at 8.0. Lower, then maintain the pool pH between 7.2-7.8.
Treat the pool water so that the pH is within the acceptable range. Correct By: 07-Oct-2022
Comments |
---|
Pool Notes: 1. Continue efforts to improve the clarity of the pool water. 2. The report was emailed to the facility. Contact Scott Bradley,R.E.H.S. (732-7614) with any questions. |